Basic configuration
Previous Top Next

graphic

1.  Run ScopeDome USB Driver program from the Start menu
2.  Press the Config button
3.  Enter the coordinates of your observatory on the Dome Site Info panel
4.  Press the button Select Scope on the Telescope tab. The ASCOM Telescope Chooser will start - choose the appropriate driver for your telescope and set the necessary parameters (COM port, etc.)

Note: If you control the telescope using  TheSky6, set the Select Scope and Park Sensor boxes into the value "TheSky6"

5.  Enter the data about the dome’s geometry and the telescope mount’s position. For more information, please visit: Dome Geometry chapter
6.  Press the Calibrate button on the Dome Mechanics panel tab and follow the instructions on the screen. For more information about calibration, please visit: Dome Calibration
7.  Enter the value of the angle formed between the north and the Home position sensor on the Sensor Position panel. You can see how to set the angle of the Home Position sensor using the Set button here: Set Home Position Sensor
8.  Enter the name of devices connected to the controller on the Relays panel / the Relays Name tab
9.  Select the weather station’s type and the sensor monitoring the cloudiness over the observatory
10.          Set the card’s type into ScopeDomeUSB Card on the Program tab on Program Flow panel on Select Io Card box.

Note: This program may work in test mode - without the driver’s card physically connected. This mode is useful to familiarize with the program or during scripts test written to automate the dome’s work. To turn on the Test mode set the card’s type into NoCard on the Program tab on the Program Flow panel on the "Select Io Card box.

Note: All the basic configuration parameters can be restored by pressing the Restore Default button by single click.